Products
Quick Links
Contact Us
WeChat: +86 15715730101
WhatsApp: +86 15715730101
Email: sales@hello-signal.com
19A07, Building N1, Binhong Business Center, Jincheng, Linan, Hangzhou, Zhejiang, China
The ZCPPF6A-05U24-PD-B1 is a 19-inch, 24-port FTP CAT6A shielded patch panel with 0.5U profile and punch down termination, designed for structured cabling projects that need compact rack density, shielding continuity, and organized permanent-link termination.
Add front view, IDC rear view, port close-up, and rack-installed application image here.
Suitable for punch down demonstration, shielding explanation, installation guide, or factory overview.
The FTP CAT6A 0.5U 24 Ports Shielded Patch Panel is a punch down type copper patch panel built for 19-inch rack environments that need 24-port density in a reduced 0.5U height. It is designed around shielded structured cabling applications where organized terminations, controlled rack layout, and permanent-link style cabling are important.
For engineering teams, the main attraction is the balance between rack-space efficiency and practical termination design. For procurement teams, the model is easy to define by SKU, packing unit, and mechanical dimensions, making it suitable for standardized deployments across structured cabling projects.
A 0.5U patch panel is valuable when rack space is tight, but it should be chosen with clear understanding of cable routing density, rear punch-down working space, and shielding continuity requirements.
This patch panel is designed for shielded copper installations that need a compact form factor without giving up structured front-port organization or punch-down IDC termination logic.
| Feature | What It Means | Project Benefit |
|---|---|---|
| 0.5U Profile | 24 ports in reduced rack height | Helps save vertical rack space |
| 24-Port 19-Inch Design | Standard rack-mount footprint | Simplifies integration into existing rack systems |
| FTP CAT6A Shielded Layout | Shielded panel structure for higher-performance cabling projects | Supports better EMC control in shielded installations |
| Punch Down Type | Rear cable termination through IDC | Suitable for permanent structured cabling terminations |
| KRONE IDC | IDC style specified as KRONE type | Useful for projects standardized around this termination approach |
| Cold Rolled Plate Construction | Metal housing in black finish | Provides a durable rack-mounted body |
| Phosphor Bronze Contacts | Tin gold 3U contact specification, customizable to 50U | Helps align contact performance with different project needs |
| Included Hardware | M6 screws and nuts, cable ties shown in packing page | Improves installation readiness at the site |
| Parameter | Specification |
|---|---|
| Product Type | FTP CAT6A 0.5U 24 ports shielded patch panel |
| SKU | ZCPPF6A-05U24-PD-B1 |
| Mounting Standard | 19-inch |
| Ports | 24 ports |
| Profile Height | 0.5U |
| Shielding Type | FTP shielded |
| Termination Type | Punch down type |
| IDC Type | KRONE IDC |
| Color | Black |
| Metal Material | Cold rolled plate |
| IDC Material | New PC |
| Terminal Material | Phosphor bronze, tin gold 3U, customizable to 50U |
| RJ45 Contact Life | 750 times min |
| IDC Life | 250 times min |
| Contact Resistance | 20M OHM |
| Insulation Resistance | <= 500M OHM @100 V DC |
| Withstand Voltage | DC1000V AC700V RMS 60HZ, 1MIN |
| Permanent Link | CAT5E permanent link: conform to ANSI/TIA/EIA 568B.2-10 |
| Storage Temperature | -40° to +70° |
| Operation Temperature | -10° to +60° |
This patch panel combines a cold rolled metal body with KRONE IDC termination and phosphor bronze contact structure. The material system is configured for repeated front-port connection cycles and structured rear punch-down installation in rack environments.
| Construction Element | Specification | Practical Meaning |
|---|---|---|
| Panel body | Cold rolled plate, black finish | Supports rack rigidity and consistent appearance |
| IDC block | KRONE IDC, new PC material | Suitable for structured punch-down terminations |
| Terminal | Phosphor bronze, tin gold 3U, customizable to 50U | Allows adjustment of contact-grade expectation for different projects |
| Front RJ45 interface | 750 mating cycles minimum | Relevant for patching frequency and service lifecycle |
| IDC termination life | 250 times minimum | Useful for understanding retermination tolerance |
If a project wants compact patch density and shielded structured cabling, this panel is a stronger fit than a basic unshielded 1U panel. But installers should still confirm rear working space for punch-down and cable dressing.
This shielded CAT6A patch panel is suitable for structured cabling projects that need fixed copper terminations in a standard rack layout while keeping vertical rack consumption lower than a traditional 1U patch panel.
| Application Scenario | Why This Panel Fits | What to Verify Before Approval |
|---|---|---|
| Shielded structured cabling rack | FTP layout supports shielded copper deployment | Grounding logic and cable compatibility |
| High-density telecom or IT cabinet | 0.5U profile saves rack height | Rear cable management and patch cord organization |
| Permanent-link termination point | Punch down IDC structure suits fixed link termination | Installer tooling and IDC standard preference |
| OEM or standard project procurement | Clear SKU, packing, and dimension data support repeat purchasing | Gold thickness customization need and carton planning |
| Rack retrofit needing space savings | Reduced height helps preserve valuable rack space | Confirm mechanical clearance and cable bend management |
The fastest correct decision is to start with three questions: does the project require shielding, does the rack benefit from 0.5U density, and does the team want punch-down IDC rear termination? If the answer is yes to all three, this panel is usually a strong fit.
| Decision Point | Choose This Panel When | Do Not Choose It When | Alternative Direction | Cost / Risk / Maintainability Impact |
|---|---|---|---|---|
| Shielding need | The project requires FTP shielded copper infrastructure | The project is fully unshielded and EMI control is not needed | Use an unshielded patch panel | Right choice avoids unnecessary cost and complexity |
| Rack-space pressure | A 0.5U panel helps preserve rack height | Rack space is not constrained and standard height is preferred | Use a standard-height panel if simpler site handling is preferred | Higher density can improve rack efficiency but may tighten rear cable work |
| Termination style | The project uses punch down IDC rear termination | The team prefers different termination architecture | Choose a panel format aligned with site practice | Correct termination match reduces installation error |
| IDC standard | KRONE IDC is compatible with installer tooling and standards | The site standard does not align with this IDC expectation | Use a panel with the required IDC format | Avoids tool mismatch and retermination risk |
| Contact requirement | Standard 3U contact is acceptable or custom 50U is specified in advance | The project has undefined contact-grade expectations | Clarify plating requirement before RFQ release | Early clarity reduces quality and procurement disputes |
| Testing expectation | The project accepts the stated permanent-link and electrical parameters | The project specification demands additional or different compliance claims | Confirm specification alignment before purchase | Avoids mismatch between submittal and project acceptance |
Choose this model when the project needs a shielded CAT6A punch-down panel in a compact 0.5U footprint and the installation team is prepared for KRONE IDC termination and high-density rear cable dressing.
A correct product decision should evaluate rack-space constraints, shielding strategy, IDC standard, packing needs, and expected service lifecycle. This helps avoid buying a technically correct panel that is inconvenient in the actual rack environment.
| Selection Factor | Question to Ask | Recommendation |
|---|---|---|
| Shielding architecture | Is the structured cabling system shielded end-to-end? | Use this panel only when the shielding strategy is defined clearly |
| Rack density | Does the project benefit from reducing patch panel height to 0.5U? | Choose 0.5U when rack space is truly valuable |
| Installation practice | Is KRONE punch down the right standard for the site team? | Confirm tool and installer familiarity before approval |
| Contact specification | Is standard 3U enough, or is higher contact customization needed? | Lock the required plating level before order release |
| Logistics | How many cartons and rack units are needed in the project shipment? | Use the packing data for carton planning and warehouse allocation |
| Service lifecycle | How often will ports be repatched or reterminated? | Review RJ45 and IDC life figures against expected maintenance frequency |
| Dimension | Value | Why It Matters |
|---|---|---|
| Overall length | 482.60 mm | Standard 19-inch rack mounting reference |
| Mounting width reference | 458.20 mm | Useful for rack alignment planning |
| Depth | 113.00 mm / 113.50 mm shown | Important for rear cable management clearance |
| Height reference | 22.25 mm | Confirms compact low-profile structure |
Packing information is important for buyers managing project quantities, carton planning, and freight efficiency. This model is packed in a straightforward format that supports bulk project purchase and warehouse handling.
| Packing Item | Specification | Procurement Meaning |
|---|---|---|
| Inner box quantity | 1 pc / inner box | Simple counting for single-unit handling |
| Carton quantity | 10 pcs / carton | Useful for project and pallet quantity planning |
| Inner box size | 51 × 10 × 5.5 cm | Helps warehouse and courier planning |
| Carton size | 53 × 42.5 × 30.5 cm | Supports freight-volume estimation |
| Accessories shown | M6 screws and nuts, cable ties | Improves installation readiness and BOM clarity |
Its main advantage is combining 24 shielded CAT6A ports with a compact 0.5U profile, helping save rack space in structured cabling projects.
It is a punch down type patch panel using KRONE IDC termination.
Choose it when the cabling system is shielded and the project needs better control of shielding continuity and structured rack termination.
Confirm the shielding strategy, IDC standard, rack-space constraints, required contact plating level, and whether the team wants a 0.5U panel instead of a standard-height alternative.
Yes. The terminal is stated as tin gold 3U and can be customized to 50U.
The product is packed 1 piece per inner box and 10 pieces per carton, which is useful for project quantity and logistics planning.
The ZCPPF6A-05U24-PD-B1 is a practical shielded CAT6A patch panel for projects that need punch-down structured cabling in a compact 0.5U rack profile. Its value comes from the combination of 24-port density, KRONE IDC termination, shielded design, and clear packing data rather than from generic marketing claims.
For the best project result, match this panel to a clearly defined shielded cabling architecture, confirm IDC and plating expectations early, and verify that the rack layout can support high-density rear cable dressing. When those conditions are met, it becomes a strong choice for organized copper structured cabling deployment.
Send your shielding requirement, rack-space constraint, IDC preference, project quantity, and contact plating requirement. ZION can help you confirm the most suitable patch panel solution before purchase.
We specializing in designing, manufacturing communications infrastructure & equipment and providing customized services for our customers!
Email:sales@hello-signal.com
Give Us A Call:+86 15715730101








WeChat: +86 15715730101
WhatsApp: +86 15715730101
Email: sales@hello-signal.com
19A07, Building N1, Binhong Business Center, Jincheng, Linan, Hangzhou, Zhejiang, China