Optical fiber systems & Copper cabling infrastructure products | High quality and excellent service at reasonable prices.

96/144/288 cores Fiber Optic Vertical Splice Closure-ZC-FV109M

ZION KNOWLEDGE BASE • FIBER MANAGEMENT • SPLICE CLOSURE SELECTION

 96/144/288 cores Fiber Optic Vertical Splice Closure-ZC-FV109M

A decision-ready guide for engineers and procurement teams selecting a field-friendly, re-enterable vertical splice closure for outdoor FTTH/ODN deployments.

Network Engineers
FTTH / ODN Contractors
ISP / Telecom Ops
System Integrators
Procurement
Project Managers

Quick Takeaway
  • Mechanical seal (M) reduces tool dependency and supports repeatable re-entry—ideal when adds/moves/changes are expected.
  • 2+8 cable entries fit branching distribution: two main entries for trunk/loop-through + eight branches for drop/service lines.
  • Engineer shortcut: verify port OD (25 mm / 18 mm) matches your cable OD, then pick tray plan (24C vs 48C) based on re-entry frequency.


96 144 288 cores Fiber Optic Vertical Splice Closure ZC FV109M2

■1) Overview: Where ZC-FV109M Fits

The ZC-FV109M is a high-capacity vertical fiber optic splice closure designed for outdoor fiber splicing, storage, and long-term protection.
With IP68 protection, PP housing, and a mechanical sealing (M) structure, it supports repeatable opening and re-sealing—reducing lifecycle risk when networks expand over time.

Field reality
Most splice closures fail in the field due to sealing workflow and port/cable mismatch, not because of splicing quality.
Mechanical sealing improves consistency and shortens re-entry time, which directly lowers truck rolls and outage risk.


Pictures for reference2

■2) Core Specifications (IP68 / PP / 2+8)

Item Specification Decision / Risk Note
Model ZC-FV109M Mechanical seal type “M” supports repeatable re-entry maintenance.
Color Black Outdoor-friendly; helps hide dirt and UV discoloration.
Protection Level IP68 Recommended for manhole/duct/high moisture environments.
Material PP (engineering plastic) Corrosion-resistant; stable mechanical structure for outdoor use.
Sealing Method (Inlets) Mechanical seal (M) Faster install, lower tool dependency, consistent sealing quality.
Inlet / Outlet 2 + 8 Supports loop-through trunk (2) + multiple distribution branches (8).
OD of Ports 2 big round ports: 25 mm
8 small round ports: 18 mm
Engineer checkpoint: cable OD must match port OD to prevent leaks and strain.
Operating Environment Temperature: −40℃ ~ +60℃
Humidity: ≤95% (at 40℃)
Pressure: 70 kPa ~ 106 kPa
Suitable for harsh climates; standardize SOP for extreme cold/heat days.
Dimension 530 × 305 mm Check cabinet/manhole clearance before mass deployment.
Key takeaway
If your project requires frequent re-entry, mechanical sealing can reduce field variability and shorten maintenance time.
Always validate 25 mm / 18 mm port OD mapping to your cable OD before finalizing procurement.


■3) Capacity & Splice Tray Configurations

ZC-FV109M supports flexible capacity plans using 24-core or 48-core booklet-style splice trays.
Choose the tray plan based on re-entry frequency and how you stage network expansion.

Target Capacity Tray Plan When to Use
96 Cores 48C × 2 pcs Fast deployment, fewer parts; stable access nodes with lower re-entry.
96 Cores 24C × 4 pcs Better control for staged rollout and frequent add operations.
144 Cores 48C × 3 pcs Balanced density and maintenance for distribution points.
144 Cores 24C × 6 pcs Best for frequent re-entry with minimal splice disturbance.
288 Cores 48C × 6 pcs High-density branching or future-proofing where upgrades are costly.
Practical rule
If the node will be reopened often, choose 24-core trays for finer management and lower splice disturbance risk.
If speed and simplicity matter most, use 48-core trays.


■4) Mechanical Seal: Install & Maintainability

Mechanical sealing improves field repeatability by reducing heating-tool dependency and enabling consistent re-sealing during upgrades.
The internal trays are turn-able like a booklet, allowing technicians to operate cables and fibers individually while keeping routing organized.

What helps engineers
  • Repeatable opening and re-sealing without heat-shrink workflow.
  • Booklet-style trays support safe re-entry and incremental expansion.
  • Designed fiber routing supports controlled bend radius and storage space.
  • Suitable for ribbon type and common optical cable applications.
What procurement should standardize
  • Cable OD mapping to ports: 25 mm (main) and 18 mm (branch).
  • Inventory plan: 96/144/288 capacity variants for site-level standardization.
  • Tray strategy alignment (24C vs 48C) with site maintenance SOP.
  • Acceptance checks (seal test + insulation resistance) for commissioning.


■5) Decision Rules / Engineer’s Shortcut

Use this quick comparison to choose capacity and tray strategy while controlling cost, risk, and maintenance time.
The goal is to prevent underbuild (forced redesign) and avoid port/cable mismatch (sealing failures).

Decision Factor Choose 96 Cores Choose 144 Cores Choose 288 Cores
Growth expectation (12–24 months) Low to moderate growth; stable access points Moderate growth; distribution nodes High growth; upgrade cost higher than initial overbuild
Re-entry frequency Occasional Regular Frequent + branching changes
Tray recommendation 48C×2 for speed
24C×4 for control
48C×3 balanced
24C×6 for staged rollout
48C×6 for future-ready density
Primary risk to manage Underbuild (future capacity short) Maintenance time + staged expansion Complexity control + long-term lifecycle cost
Cost/Risk Driver What It Impacts How to Control It
Port OD mismatch (25/18 mm) Sealing failure, cable strain, water ingress Confirm cable OD range in BOM; sample-fit before rollout
Re-entry workload Truck rolls, downtime, OPEX Mechanical seal + 24C trays when frequent adds are expected
Capacity underbuild Forced redesign and replacement Plan 12–24 months growth; consider 144/288 at high-growth nodes


Standard Accessories 2

■6) Typical Applications & Deployment Notes

Scenario Why ZC-FV109M Fits Recommended Setup
ODN loop-through distribution 2 main entries support trunk pass-through; 8 branches support drops 144 cores + 24C trays for staged expansion and clean re-entry
Outdoor access nodes (FTTH/FTTB) IP68 protection, reliable housing, convenient maintenance 96 cores + 48C trays for fast deployment
High-growth service areas Big capacity reduces future redesign and node replacement 288 cores + 48C trays for future-ready density
Manhole / duct environments IP68-rated sealing supports high moisture and dust Commission with seal + insulation checks; verify port OD mapping


■7) Reliability & Acceptance Checklist

Use the following acceptance checks to validate sealing, safety, and fiber routing performance during commissioning.
These checks reduce post-install failures and improve long-term maintainability.

Practical rule
Combine seal verification (pressurization + water observation) with bend radius discipline (≥ 40 mm) and tensile controls.
Most outage tickets trace back to these controllable factors.
Test / Requirement Target Why It Matters
Seal performance After sealing: inflate to 100 kPa, soak in water, observe 15 minutes — no bubbles Direct indicator of sealing integrity and installation quality
Insulation resistance > 20 kMΩ between metal work piece and earth Electrical safety and fault risk reduction
Pressurization withstand No breakdown or flashover under DC 15 kV / 1 minute Improves reliability in complex outdoor environments
Fiber bend radius Curvature radius ≥ 40 mm inside tray, without extra loss Prevents micro-bending loss and long-term attenuation growth
Axial tensile strength ≥ 1000 N Reduces risk from pulling forces during installation
Service life 25 years Lifecycle planning for long-term network assets


■8) Packaging & Logistics

Item Value Planning Note
Product Dimension 530 × 305 mm Confirm clearance in cabinet/manhole and mounting space.
Carton Size 60 × 47 × 50 cm Useful for container loading and site storage planning.
Gross Weight / Carton 18 kgs Plan safe handling; confirm courier limits if applicable.
PCS / Carton 4 pcs Set spare ratio by node criticality and maintenance frequency.


■9) FAQ (Engineering & Procurement)

Q: Why choose mechanical seal instead of heat-shrink?
Mechanical sealing reduces tool dependency and helps standardize field quality. It also supports repeatable re-entry, which is valuable when fiber adds are expected over time.
Q: What is the most common selection mistake?
Port/cable OD mismatch. Always verify your cable OD range matches 25 mm (main) and 18 mm (branch) ports before committing to bulk procurement.
Q: 24C trays or 48C trays — which is better?
48C trays reduce part count and speed up deployment. 24C trays provide finer management and reduce splice disturbance risk during frequent re-entry and staged rollout.

■Conclusion

The ZC-FV109M vertical splice closure delivers a strong balance of IP68 protection, mechanical sealing consistency, and high-capacity tray scalability (96/144/288 cores).
For a reliable outcome, standardize your selection using three steps: (1) confirm 2+8 entry topology fits your distribution plan, (2) verify 25 mm / 18 mm port OD matches your cable OD, and (3) choose 24C vs 48C trays based on re-entry frequency and maintenance SOP.

FINAL CTA — Send Your Project Parameters
Share your target core count (96/144/288), cable OD range, entry plan (2+8), installation scenario (aerial / manhole / duct), and tray preference (24C / 48C).
We will recommend the best configuration and provide datasheet/quote support.

Email us, Call us, Meeting online with us!

Tell us about your purchasing plans!

We specializing in designing, manufacturing communications infrastructure & equipment and providing customized services for our customers!

Email:sales@hello-signal.com
Give Us A Call​​:+86 15715730101

Get A Free Quote

Fill Out The Form To Get Our Latest Catalog