Optical fiber systems & Copper cabling infrastructure products | High quality and excellent service at reasonable prices.

36/48 cores Fiber Optic Vertical Splice Closure-ZC-FV108H-PLC

SKU FV108H-PLC Category

ZION KNOWLEDGE BASE • FIBER OPTIC SPLICE CLOSURE • OUTDOOR IP68

ZC-FV108H-PLC: 36/48 Cores Fiber Optic Vertical Splice Closure (Dome Type)

A field-ready, engineer-friendly closure for outdoor splicing, distribution, and long-life network protection—optimized for maintainability and deployment speed.

Network Engineers
FTTx / OSP Teams
ISP Operators
System Integrators
Procurement
Project Managers

Quick Takeaway (Engineer View)
  • Choose this model when you need IP68 outdoor sealing + 48-core (2×24 trays) capacity in a vertical dome form factor.
  • Plan around 2+4 ports with 6×OD 18mm small round ports—validate cable OD and site routing before mass rollout.
  • For long-life OSP networks, prioritize re-entry maintainability, proper fiber bend radius management, and standardized accessory kits.


36 48 cores Fiber Optic Vertical Splice Closure ZC FV108H PLC 2 拷贝

■
1) Overview & Where It Fits

The ZC-FV108H-PLC is a vertical (dome-type) outdoor fiber optic splice closure built for splicing, protection, distribution, and fiber storage in OSP/FTTx networks. It is commonly used to connect distribution cable and drop/indoor cable in outdoor environments where sealing requirements are stricter than terminal boxes.

Field reality / Practical rule
In outdoor deployments, the failure mode is rarely “bad splicing”—it’s usually water ingress, poor port sealing, or cable strain. Select closures by sealing grade, port/cable fit, and re-entry maintenance first—then look at capacity.


Pictures for reference

■
2) Core Specs (What Matters in OSP)

Below are the deployment-critical parameters that affect site compatibility, sealing reliability, and long-term maintainability.

Item Specification Why It Matters
Model ZC-FV108H-PLC Use for BOM standardization and site documentation.
Type / Form Vertical (Dome) Splice Closure Compact layout, easy re-entry; common for manhole/duct/aerial use.
Protection Level IP68 Critical for water immersion risk (manhole/duct) and heavy rain zones.
Capacity 48 cores (2 pcs × 24-core trays); Splice tray: max 24 cores / pc Defines splice density and future expansion headroom.
Adapter Capacity (Max) 36 pcs adapter (max) Helps plan distribution/patching strategy in field deployments.
Sealing Method (Inlets) Mechanical sealing Focus on consistent torque/fit; improves re-entry and maintenance cycles.
Inlet / Outlet 2 + 4 Match feeder/distribution topology and splitting/branch requirements.
Port OD Small round ports: 6 × OD 18mm Cable OD mismatch is a top cause of sealing failures—validate before rollout.
Operating Temperature -40°C to +60°C Ensures stable sealing and housing performance in harsh climates.
Relative Humidity ≤95% (at 40°C) Relevant for tropical/high-humidity OSP deployments.
Atmospheric Pressure 70 kPa to 106 kPa Useful for altitude and environmental compliance considerations.
Dimensions 470 × 220 mm Affects manhole space planning and mounting logistics.
Material / Color PP / Black Engineering plastic housing; outdoor durability and appearance consistency.
Weight / Packing Net: 2.15 kg (max) • Gross/carton: 18 kg • 6 pcs/carton Impacts shipping cost, handling, and warehouse planning.

Key takeaway
If your projects involve manholes/ducts or harsh weather, IP68 + mechanical sealing + verified cable OD should be treated as a “must-pass” gate before considering tray layout or accessory preferences.


■
3) Decision Rules / Engineer’s Shortcut

Use the table below as a quick filter to decide whether ZC-FV108H-PLC is the correct closure for your site. This is designed for fast engineering review and procurement alignment.

Decision Gate Choose ZC-FV108H-PLC When… Avoid / Consider Another Option When… Procurement Risk Note
Environment Outdoor OSP sites need IP68 sealing (duct/manhole/rain exposure). Indoor/low-risk areas where IP-rated sealing is not required. Wrong sealing grade causes repeat truck rolls and SLA penalties.
Capacity You need up to 48 cores with 2×24 trays and clean routing. You expect higher core count expansion beyond this closure’s practical limit. Under-sizing capacity increases future retrofit costs and downtime.
Port / Cable Fit Your cable OD matches OD 18mm small round ports (6 ports total). Your feeder cable OD exceeds port range or requires different entry geometry. OD mismatch is the #1 sealing failure—confirm cable jacket OD in RFQ.
Maintainability You want mechanical sealing and repeated re-entry without special tools. You require fully heat-shrink-only closure workflow or special operator preference. Maintenance approach affects training, tooling, and field time per job.
Lifecycle You prioritize long-life operation with a target 25-year service life. You plan short-term temporary deployments where low-cost enclosures are acceptable. Lifecycle focus reduces long-term OPEX even if CAPEX is slightly higher.

Field reality / Practical rule
If your team has no standardized “cable OD check” step, add it now. In large deployments, a small mismatch across sites can create a wave of water ingress returns and rework.


■
4) Ports, Cables & Fiber Management

The ZC-FV108H-PLC supports typical OSP cable workflows including direct connection and splitting connection. It is applicable to ribbon type optical cables and common optical cables, with splice trays designed for clean routing and adequate fiber storage.

Planning Item ZC-FV108H-PLC Reference Engineer Notes
Total ports Inlet/Outlet: 2 + 4 (6 total) Align port use with feeder, distribution, and branch paths; label ports for re-entry.
Port OD Small round ports: 6 × OD 18mm Validate cable OD range and sealing components during FAT/SAT.
Splice tray layout Max 24 cores / tray • Typical: 2 trays for 48 cores Keep slack consistent; avoid overcrowding which increases micro-bending risk.
Bend radius control Designed to maintain appropriate fiber curvature (field practice recommended) Maintain clean routing and avoid sharp turns—especially near entry points and tray hinges.

Key takeaway
Treat ports + cable OD as the primary compatibility gate, and tray management as the maintainability gate. This prevents sealing-related returns and reduces time per re-entry job.


■
5) Deployment Scenarios & Site Checklist

This closure is suitable for typical OSP installation conditions such as overhead (aerial), manhole/duct, and embedded situations, where stable structure and sealing performance are required.

Scenario Why It Works Site Checklist (Fast Pass)
Manhole / Duct IP68 sealing supports high moisture/temporary immersion risk. Confirm space for 470×220mm • Verify port OD • Add strain relief.
Aerial Optional aerial accessories enable overhead deployment workflows. Check mounting kit • Cable sag/strain • UV/weather exposure plan.
Embedded / Outdoor Cabinet Mechanical sealing helps re-entry without special tools. Label trays/ports • Reserve slack • Document splice map for O&M.


■6) Accessories, Packing & Logistics

Standard accessories improve field installation consistency and reduce missing-tool delays. For procurement, confirm accessory completeness by carton and by job kit.

Category Included Items (Standard Accessories) Notes
Consumables Tag paper (1) • Sand paper (1) • Silver paper (1) • Cleaning tissue (1) • Insulating tape (1) Ensure the kit matches your field SOP for labeling and cleaning.
Cable Management Cable ties 3mm×10mm (12 pcs) • Fiber protective tube (3 pcs) Use consistent tie-down points to keep routing repeatable across sites.
Sealing / Ports Plastic plug + Rubber plug (10 pcs) • Plastic plug (4 pcs) Port sealing parts are critical—inspect for damage before installation.
Heat Shrink Heat-shrink sleeve 1.0mm×3mm×60mm (12–144 pcs) Quantity may vary by configuration—confirm exact count in the PO.
Optional Pole accessories (1 pc) • Aerial accessories (1 pc) Request based on installation type; standardize to reduce field variance.

Transportation & storage (Operational notes)
  • Avoid raining, sun exposure, and squeezing during transportation.
  • Store in warehouse avoiding moisture, sun, and fire. Suggested storage temperature: 25°C to +40°C.
  • Protect special parts that are easily damaged during transportation.


Standard Accessories

■
7) Cost, Risk & Maintainability Notes

For large-scale rollout, cost is more than unit price. The key drivers are truck rolls, fault isolation time, and re-entry effort. The closure design supports repeated opening without special tools and emphasizes organized tray routing.

Driver What to Control Typical Failure if Ignored Actionable Rule
Sealing integrity Port OD fit, sealing parts condition, proper closure assembly Water ingress, corrosion, intermittent attenuation Add OD check in RFQ + field checklist; inspect plugs before install.
Fiber routing Bend radius, slack management, tray labeling Micro-bending loss, hard-to-debug degradation Standardize routing path; document splice map per tray.
Maintainability Re-entry time, tool requirements, accessory completeness Long restoration time, inconsistent field quality Bundle accessories per job kit; keep SOP aligned with mechanical sealing.

Key takeaway
In procurement terms: your biggest hidden cost is repeat visits. Buying a closure that is easy to seal correctly and easy to re-enter is often cheaper over the network’s life than optimizing for unit price alone.


 Optional Accessories

■
8) Conclusion & FINAL CTA

The ZC-FV108H-PLC is a practical IP68-rated vertical splice closure for OSP environments that require reliable sealing, structured tray management, and repeatable field maintenance. For best results, treat cable OD validation and port sealing parts inspection as mandatory gates during both engineering design and installation.

Actionable recommendation: for each project, submit your cable OD, core count target, port usage topology, and installation method (manhole/duct/aerial). This ensures the closure configuration, accessories, and packing strategy match your deployment reality.

FINAL CTA — Send Your Parameters for Verification
Please share: fiber core count, cable OD, port plan (2+4), installation scenario, and any accessory requirements (pole/aerial). Our team will recommend the right configuration and provide a datasheet/quote.

Email us, Call us, Meeting online with us!

Tell us about your purchasing plans!

We specializing in designing, manufacturing communications infrastructure & equipment and providing customized services for our customers!

Email:sales@hello-signal.com
Give Us A Call​​:+86 15715730101

Get A Free Quote

Fill Out The Form To Get Our Latest Catalog