Products
Quick Links
Contact Us
WeChat: +86 15715730101
WhatsApp: +86 15715730101
Email: sales@hello-signal.com
19A07, Building N1, Binhong Business Center, Jincheng, Linan, Hangzhou, Zhejiang, China

| Zion Code | Zion Description |
| 7217060 | 10G Passive SFP+ TO SFP+ Direct Attach Cable |
The 7217060 10G SFP+ direct attach cables assembly are based on 10G Ethernet IEEE802.3ae standard,fiber channel and SFF-8431standard,and the passive SFP+ Cable is low cost alternative
for short reach applications in data center cabling.
| Connector Type | SFP+ to SFP+ | Vendor Name | Zion Communication | |||||
| Max Data Rate | 10Gbps | Wire AWG | 24AWG – 30AWG | |||||
| Max Cable Distance 1 | 10m | Cable Type | Passive Twinax | |||||
| Power Supply | 3.3V | Operating Temp. | 0°C to 70°C (32°F to 158°F) | |||||

| Zion Code | Zion Description | |||||||
| 7217010 | 100G Passive QSFP28 TO QSFP28 Direct Attach Cable | |||||||
| 7217020 | 100G Passive QSFP28 TO 4×SFP28 Direct Attach Cable | |||||||
| 7217030 | 40G Passive QSFP+ TO QSFP+ Direct Attach Cable | |||||||
| 7217040 | 40G Passive QSFP+ TO 4×SFP+ Direct Attach Cable | |||||||
| 7217050 | 25G Passive SFP28 TO SFP28 Direct Attach Cable | |||||||
| 7217060 | 10G Passive SFP+ TO SFP+ Direct Attach Cable | |||||||
| Item | Requiement | Test Condition | ||||||
| Diffrential Impedance |
Cable Impedance | 105±5 Ω | Rise time of 35ps (20 % – 80 %). |
|||||
| Paddle Card Impedance | 100±10 Ω | |||||||
| Cable termination impedance | 100±15 Ω | |||||||
| [Differential (Input/Output)Return loss SDD11/SDD22] |
≤ – 10 dB | 10MHz≤f ≤5GHz | ||||||
| [Insertion Loss Deviation] | -0.176*f – 0.7 ≤ ILD ≤ 0.176* f + 0.7 | 10MHz≤f ≤5GHz | ||||||
| [MDNEXT(multiple disturber near-end crosstalk)] |
≥26dB | 10MHz≤f ≤5GHz | ||||||
| AWG | Length | 600Mhz | 1.25GHz | 2.5GHz | 5.0GHz | |||
| 30 AWG | Max. 1m | 2.0dB | 3.0dB | 4.5dB | 7.5dB | |||
| 28 AWG | Max. 3m | 4.0dB | 5.5dB | 7.5dB | 12.0dB | |||
| 26 AWG | Max. 5m | 5.5dB | 7.0dB | 10.0dB | 16.0dB | |||
| 24 AWG | Max. 10m | 6.5dB | 10.0dB | 14.0dB | 21.0dB | |||
| Item | Requiement | Test Condition | ||||||
| Operating Temp. Range | -20°C to +75°C | Cable operating temperature range. | ||||||
| Storage Temp.Range (in packed condition) |
-40°C to +80°C | Cable storage temperature range in packed condition. |
||||||
| Thermal Cycling Non-Powered |
No evidence of physical damage | EIA-364-32D, Method A, -25 to 90C, 100 cycles, 15 min. dwells |
||||||
| Salt Spraying | 48 hours salt spraying after shell corrosive area less than 5%. |
EIA-364-26 | ||||||
| Mixed Flowing Gas | Pass electrical tests per 3.1 after stressing. (For connector only) |
EIA-364-35 Class II,14 days. | ||||||
| Temp. Life | No evidence of physical damage | EIA-364-17C w/ RH, Damp heat 90℃ at 85% RH for 500 hours then return to ambient |
||||||
| Cable Cold Bend | 4H,No evidence of physical damage | Condition: -20℃±2℃, mandrel diameter is 6 times the cable diameter. |
||||||
| Item | Requiement | Test Condition | ||||||
| Vibration | Pass electrical tests per 3.1 after stressing. |
Clamp & vibrate per EIA-364-28E,TC-VII, test condition letter – D, 15 minutes in X, Y & Z axis. |
||||||
| Twist | No evidence of physical damage | Twist cable 180° (±90° from nominal position) for 100 cycles at 30 cycles per minute with a 0.5kg load applied to the cable jacket.Clamp position: 300mm | ||||||
| Cable Flex | No evidence of physical damage | Flex cable 180° for 20 cycles (±90° from nominal position) at 12 cycles per minute with a 1.0kg load applied to the cable jacket. Flex in the boot area 90º in each direction from vertical. Per EIA-364-41C | ||||||
| Cable Plug Retention in Cage |
90N Min. No evidence of physical damage |
Force to be applied axially with no damage to cage. Per SFF 8661 Rev 2.1 Pull on cable jacket approximately 1 ft behind cable plug. No functional damage to cable plug below 90N. Per SFF-8432 Rev 5.0 |
||||||
| Cable Retention in Plug | 90N Min. No evidence of physical damage |
Cable plug is fixtured with the bulk cable hanging vertically. A 90N axial load is applied (gradually) to the cable jacket and held for 1 minute. Per EIA-364-38B |
||||||
| Mechanical Shock | Pass electrical tests Per 3.1 after stressing. |
Clamp and shock per EIA-364-27B, TC-G, 3 times in 6 directions, 100g, 6ms. |
||||||
| Cable Plug Insertion | 40N Max.(QSFP28) | Per SFF8661 Rev 2.1 | ||||||
| Cable plug Extraction | 30N Max. (QSFP28) | Place axial load on de-latch to de-latch plug. Per SFF8661 Rev 2.1 |
||||||
| Durability | 50 cycles,No evidence of physical damage | EIA-364-09, perform plug &unplug cycles:Plug and receptacle mate rate: 250times/hour. 50times for QSFP28/SFP28 module (CONNECTOR TO PCB) | ||||||


We specializing in designing, manufacturing communications infrastructure & equipment and providing customized services for our customers!
Email:sales@hello-signal.com
Give Us A Call:+86 15715730101








WeChat: +86 15715730101
WhatsApp: +86 15715730101
Email: sales@hello-signal.com
19A07, Building N1, Binhong Business Center, Jincheng, Linan, Hangzhou, Zhejiang, China